Hematology Analyzer, Hemoglobin, POCTAbstract
Hemoglobin is a protein molecule in red blood cells that carries O2 throughout the body. Hemoglobin contains iron which makes blood red. The hemoglobin level is a measure of the respiratory pigment present in the erythrocytes, which is used to determine anemia. This study was to see if there were differences in the results of hemoglobin levels using a hematology analyzer and POCT. This study used a hematology analyzer and POCT to determine the accuracy of the results obtained on the examination of hemoglobin levels. The aim of this study was to determine differences in the results of hemoglobin levels using a hematology analyzer and POCT. This type of research is analytic observational with a cross sectional approach. This study used venous blood samples using the hematology analyzer method and capillary blood samples using the POCT method as many as 54 samples. Collecting data using purposive sampling technique. The research was conducted in May 2023. The analytical test used the Independent T Test. Based on the research results, the p-value = 0.212 so that H0 is accepted, which means that there is no difference in the results of hemoglobin levels using a hematology analyzer and POCT. Based on the independent t test, the results obtained were a p-value of 0.212, which means that there was no difference in the results of hemoglobin levels using a hematology analyzer and POCT.
References
Aliviameita, A., & Puspitasari. (2019). Buku Ajar Hematologi. In Buku Ajar Mata Kuliah Hematologi.
Astika, Y., & Iswanto, R. (2018). Perbandingan hasil pemeriksaan kadar asam urat menggunakan metode spektrofotometri dan metode PCOT (Point Of Care Testing) pada pasien Puskesmas Poasia Kendari Sulawesi Tenggara (Sultra). Jurnal MediLab Mandala Waluya Kendari, 2(2), 9–14. https://doi.org/10.36566/medilab.v2i02.17
Gilang, N., & Nur, M. (2019). Pemanfaatan Persamaan Regresi untuk Meningkatkan Keandalan Diagnostik POCT Menggunakan Sampel Darah Vena. In Universitas Nahdlatul Ulama Surabaya. http://repository.unusa.ac.id/id/eprint/646
Indriawati, R. (2016). Kajian terhadap Pemeriksaan Hemoglobin (Hb) Metode Sahli dan Talquist. In Mutiara Medika (Vol. 2, Issue 2, pp. 79–87).
Kadri, H. (2012). Hemoprotein dalam Tubuh Manusia. Jurnal Kesehatan Andalas, 1(1), 22–30. https://doi.org/10.25077/jka.v1i1.5
Lailla, M., Zainar, Z., & Fitri, A. (2021). Perbandingan Hasil Pemeriksaan Hemoglobin Secara Digital Terhadap Hasil Pemeriksaan Hemoglobin Secara Cyanmethemoglobin. Jurnal Pengelolaan Laboratorium Pendidikan, 3(2), 63–68. https://doi.org/10.14710/jplp.3.2.63-68
Maciel, T. E. S., Ricardo, C.?; S., & Beltrame, ; Miriam Perlingeiro. (2014). Performance evaluation of the Sysmex XE-2100D automated hematology analyzer. Laboratory Hematology, 50(1), 26–35.
Nidianti, E., Nugraha, G., Aulia, I. A. N., Syadzila, S. K., Suciati, S. S., & Utami, N. D. (2019). Pemeriksaan Kadar Hemoglobin dengan Metode POCT (Point of Care Testing) sebagai Deteksi Dini Penyakit Anemia Bagi Masyarakat Desa Sumbersono, Mojokerto. Jurnal Surya Masyarakat, 2(1), 29. https://doi.org/10.26714/jsm.2.1.2019.29-34
Nuradi, J. (2020). Hubungan Kadar Hemoglobin Dan Nilai Hematokrit Pada Perokok Aktif. Jurnal Media Analis Kesehatan, 11(2), 150. https://doi.org/10.32382/mak.v11i2.1829
Puspitasari, P., Aliviameita, A., Rinata, E., Yasmin, R. A. Y., & Saidah, S. N. (2020). Perbedaan Hasil Pemeriksaan Hemoglobin Antara Metode Point of Care Testing Dengan Metode Sianmethemoglobin Pada Ibu Hamil. Jurnal Analis Kesehatan, 9(1), 24. https://doi.org/10.26630/jak.v9i1.2113
Saputra, O. D., Studi, P., Teknologi, D. I. V, Medis, L., Sains, F., & Palembang, I. M. (2022). PERBEDAAN PEMERIKSAAN DARAH SEGERA DAN DITUNDA SELAMA 6 JAM PADA SUHU 4-8 O C TERHADAP KADAR HEMOGLOBIN DENGAN HEMATOLOGY ANALYZER DOI?: https://doi.org/10.36729 Jurnal ‘ Aisyiyah Medika PENDAHULUAN Laboratorium merupakan suatu menyebutkan pemeriksaan bah. 7, 49–56.
Saputro, D. A., & Junaidi, S. (2015). Pemberian vitamin c pada latihan fisik maksimal dan perubahan kadar hemoglobin dan jumlah eritrosit. Journal of Sport Sciences and Fitness, 4(3), 32–40.
Susanti, Y. E., & Wirjatmadi, B. (2017). EFEK EKSTRAK MELON (Cucumis melo) dan GliadinTERHADAP KADAR Hb DAN HbCO TIKUS WISTAR JANTAN YANG DIPAPAR ASAP ROKOK. The Indonesian Journal of Public Health, 11(1), 78. https://doi.org/10.20473/ijph.v11i1.2016.78-88
Triwinarni, C., Hartini, T. N. S., & Susilo, J. (2017). Hubungan Status Gizi dengan Kejadian Anemia Gizi Besi (AGB) pada Siswi SMA di Kecamatan Pakem. Jurnal Nutrisia, 19(1), 61–67. https://doi.org/10.29238/jnutri.v19i1.49
Yusniati, Y. (2019). Pengaruh Variasi Waktu Inkubasi Terhadap Kadar Hemoglobin Metode Drabkin’s Dengan Mikro Lab 300. Jurnal Temapela, 2(2), 86–89. https://doi.org/10.25077/temapela.2.2.86-89.2019
Published
How to Cite
Issue
Section
Copyright (c) 2024 Anisatuz Zalfa, Gilang Nugraha, Wieke Sri Wulan, Endah Prayekti
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.